| Date | Description | Cell status | Previous availability | Medium | Temperature (°C) | Light condition | Rotation (rpm) | Subculture (days) | Transfer volume (mL) | Transfer method | Medium volume (mL) | Container | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2002-04-01 | RIKEN Cell Bank | Living cells | Available | Jouanneau and Péaud-Lenoël medium, 1 µM NAA, pH 5.7 | 22 | light (40-100 µE/s/m2) | 120 | 14 | 2 | 80 | Erlenmeyer flask (300-mL) | |
| 2003-05-14 | Release | Living cells | Available | Jouanneau and Péaud-Lenoël medium, 1 µM NAA, pH 5.7 | 22 | light (40-100 µE/s/m2) | 120 | 14 | 2 | 80 | Erlenmeyer flask (300-mL) | |
| 2014-11-07 | Living cells | Available | Jouanneau and Péaud-Lenoël medium, 1 µM NAA, pH 5.7 | 22 | light (40-100 µE/s/m2) | 120 | 14 | 2 | 80 | Erlenmeyer flask (300-mL) | ||
| 2017-10-01 | Living cells | Available | Jouanneau and Péaud-Lenoël medium, 1 µM NAA, pH 5.7 | 22 | light (PPFD 40-42 µmol m-2 s-1) | 120 | 14 | 2 | 80 | Erlenmeyer flask (300-mL) | ||
| 2019-02-07 | Living cells | Available | Jouanneau and Péaud-Lenoël medium, 1 µM NAA, pH 5.7 | 22 | light (PPFD 40-42 µmol m-2 s-1) | 120 | 14 | 2.4 | 80 | Erlenmeyer flask (300-mL) | ||
| 2023-11-01 | Present | Living cells | Available | Jouanneau and Péaud-Lenoël medium, 1 µM NAA, pH 5.7 | 22 | light (PPFD 40-42 µmol m-2 s-1) | 120 | 14 | 2–3 | 80 | Erlenmeyer flask (300-mL) |